1)在主控室、高压配电室、二次电缆沟道、就地端子箱等处,使用截面为100mm2的专用铜缆与变电站主接地网紧密连接的等电位接地网。
2)在主控室的电缆沟内设截面不小于100mm2的专用铜排,该专用铜排首末端连接,形成主控室内的等电位接地网。主控室内的等电位接地网必须用至少4根以上,截面不小于50mm2的铜排与主接地网可靠连接。
3)保护测控屏及综合自动化屏,屏内的下部设截面不小于100mm2的专用接地铜排。接地铜排应用截面不小于50mm2的铜辩与主控室内的等电位接地网相连。屏上装置的接地端子应用截面不小于4mm2的多股铜线和接地铜排相连。

英语

1) In the main control room, high voltage distribution room, secondary cable channel, local terminal box and other places, the use of 100mm2 section of special copper cable and substation main grounding grid closely connected equipotential grounding grid.
2) A special copper bar with a section not less than 100mm2 is installed in the cable trench of the main control room. The head and end of the special copper bar are connected to form an equipotential grounding grid in the main control room. The equipotential grounding grid in the main control room must be connected with the main grounding grid reliably by at least four copper bars with a cross section of not less than 50 mm2.
3) Protect the monitoring and control screen and the integrated automation screen. The lower part of the screen is equipped with a special grounding copper bar whose cross section is not less than 100mm2. The application section of grounding copper bars is not less than 50 mm2. The copper bars are connected with the equipotential grounding grid in the main control room. The grounding terminal of the device on the screen shall be connected with the grounding copper bar by multi stranded copper wire with a cross section of not less than 4mm2.

"1)在主控室、高压配电室、二次电缆沟道、" 的相关翻译

1)在主控室、高压配电室、二次电缆沟道、就地端子箱等处,使用截面为100mm2的专用铜缆与变电站主接地网紧密连接的等电位接地网。2)在主控室的电缆沟内设截面不小于100mm2的专用铜排,该专用铜排首末端连接,形成主控室内的等电位接地网。主控室内的等电位接地网必须用至少4根以上,截面不小于50mm2的铜排与主接地网可靠连接。3)保护测控屏及综合自动化屏,屏内的下部设截面不小于100mm2的专用接地铜排。接地铜排应用截面不小于50mm2的铜辩与主控室内的等电位接地网相连。屏上装置的接地端子应用截面不小于4mm2的多股铜线和接地铜排相连。用英语怎么说? 1) In the main control room, high voltage distribution room, secondary cable channel, local terminal box and other places, the use of 100mm2 section of special copper cable and substation main grounding grid closely connected equipotential grounding grid. 2) A special copper bar with a section not less than 100mm2 is installed in the cable trench of the main control room. The head and end of the special copper bar are connected to form an equipotential grounding grid in the main control room. The equipotential grounding grid in the main control room must be connected with the main grounding grid reliably by at least four copper bars with a cross section of not less than 50 mm2. 3) Protect the monitoring and control screen and the integrated automation screen. The lower part of the screen is equipped with a special grounding copper bar whose cross section is not less than 100mm2. The application section of grounding copper bars is not less than 50 mm2. The copper bars are connected with the equipotential grounding grid in the main control room. The grounding terminal of the device on the screen shall be connected with the grounding copper bar by multi stranded copper wire with a cross section of not less than 4mm2.

1)在主控室、高压配电室、二次电缆沟道、就地端子箱等处,使用截面为100mm2的专用铜缆与变电站主接地网紧密连接的等电位接地网。2)在主控室的电缆沟内设截面不小于100mm2的专用铜排,该专用铜排首末端连接,形成主控室内的等电位接地网。主控室内的等电位接地网必须用至少4根以上,截面不小于50mm2的铜排与主接地网可靠连接。3)保护测控屏及综合自动化屏,屏内的下部设截面不小于100mm2的专用接地铜排。接地铜排应用截面不小于50mm2的铜辩与主控室内的等电位接地网相连。屏上装置的接地端子应用截面不小于4mm2的多股铜线和接地铜排相连。用英语怎么说? 1) In the main control room, high voltage distribution room, secondary cable channel, local terminal box and other places, the use of 100mm2 section of special copper cable and substation main grounding grid closely connected equipotential grounding grid. 2) A special copper bar with a section not less than 100mm2 is installed in the cable trench of the main control room. The head and end of the special copper bar are connected to form an equipotential grounding grid in the main control room. The equipotential grounding grid in the main control room must be connected with the main grounding grid reliably by at least four copper bars with a cross section of not less than 50 mm2. 3) Protect the monitoring and control screen and the integrated automation screen. The lower part of the screen is equipped with a special grounding copper bar whose cross section is not less than 100mm2. The application section of grounding copper bars is not less than 50 mm2. The copper bars are connected with the equipotential grounding grid in the main control room. The grounding terminal of the screen device is connected with multiple copper wires and grounding copper bars whose cross section is not less than 4 mm2.

百度翻译 英语在线翻译 有道翻译 汉译英 英语翻译 谷歌翻译 英译汉 在线翻译 百度在线翻译 百度在线翻译 英文翻译 中译英 韩文翻译

在线翻译说明

1、支持多种语言的在线翻译,例如:英译汉、汉译英、中英互译、中日互译、中韩互译、中法互译等;

2、可自动识别待翻译内容语种,自动输出翻译后的结果;

3、在线翻译功能与市场同类产品(例如谷歌在线翻译、百度在线翻译、有道在线翻译)相差无几;

4、在线翻译器提供免费在线翻译服务,不收取任何形式的费用;

目前可在线翻译的语言

中文、英语、日语、韩语、法语、德语、俄语、意大利语、繁体中文、粤语、文言文、西班牙语、泰语、阿拉伯语、葡萄牙语、希腊语、荷兰语、波兰语、保加利亚语、爱沙尼亚语、丹麦语、芬兰语、捷克语、罗马尼亚语、斯洛文尼亚语、瑞典语、匈牙利语、等。

在线翻译为您提供百度翻译,英语在线翻译,有道翻译,汉译英,英语翻译,谷歌翻译,英译汉,在线翻译,百度在线翻译,百度在线翻译,英文翻译,中译英,韩文翻译,日文翻译,中英互译,翻译在线,翻译器,谷歌在线翻译
在线翻译查询 全部查询
©2018 在线翻译 闽ICP备07503221号-6